题目内容

Consider a lead-acid battery with 500 Ah capacity and a rated voltage of 12 V.What is the total capacity of energy in watt-hours that can be stored in the battery? ______

查看答案
更多问题

Which of the following statements is NOT true about solar inverters?

A stand-alone inverter is supposed to work as an AC voltage source for a specified range of AC loads.
B. An ideal grid-tied inverter has its operational voltage and frequency synchronized with those of the grid.
C. A bimodal inverter can power backup loads even if the grid-connection is disrupted.
D. An ideal grid-tied inverter works as a perfect voltage source, and changes the grid voltage and frequency to match its own.

Consider the following statements related to the field of MPPT techniques:a) The PV output is never steady at the MPP.b) Inclusion of a pilot solar cell can improve the PV module's yield.c) The hardware complexity is high for implementing this design.d) The output of the PV module is maximum only if load resistance = \(\frac{V_{mpp}}{I_{mpp}}\).Consider the following conditions at the PV output:i) An MPPT device implementing Fractional Open-Circuit Voltage method.ii) An MPPT device implementing Incremental Conductance method.iii) No MPPT device connected; solar module directly connected to the load.iv) An MPPT device implementing Perturb and Observe method. Which of the following matches the statements a) through d) with the right PV output conditions in i) through iv)?

A. a) - iv), b) - i), c) - iii), d) - ii).
B. a) - i), b) - iv), c) - ii), d) - iii).
C. a) - iv), b) - ii), c) - i), d) - ii).
D. a) - iv), b) - i), c) - ii), d) - iii).

With respect to a PV module's I-V and P-V curves, and the module's operating point, consider the following statements: a) When the operating point of the PV module is on the MPP (maximum power point), \(P_{mpp} \lt V_{oc} \times I_{sc} \). b) For a given irradiance and temperature condition, and a uniformly illuminated (all solar cells receive the same illumination) module with perfectly functional solar cells, there is one and only one MPP defined for the PV module. c) Assume that a simple fixed load of pure resistance R is connected directly to the PV module, and no MPPT device is connected to this setup. Under such a scenario, the operating point of the PV module will always coincide with the MPP, irrespective of the illumination conditions.d) The curvature of the I-V characteristics of a module around the region of MPP can be looked upon as a result of the non-ideal resistances of the solar cells that make up the module.Which of the above statements are true?

A. a) only
B. a), c) and d)
C. All statements
D. a), b) and d)
E. a) and b)

What is the new power output of the PV module in watts, under the ambient temperature of 15°C and 1000 W/m² irradiance? ______

答案查题题库